CFNJC - N5881B H20 BASE COAT HARDENER
- MSDS: CFNJC
- Manufacturer: NILES CHEMICAL PAINT CO
- Product Name: N5881B H20 BASE COAT HARDENER
- National Stock Number: 8010-01-426-5483
Product Identification
Product ID:N5881B H20 BASE COAT HARDENER
MSDS Date:01/10/1995
FSC:8010
NIIN:01-426-5483
Kit Part:Y
MSDS Number: CFNJC
Responsible Party
NILES, MI 49120
US
Emergency Phone: 219-236-5856
Info Phone: 616-683-3377
Preparer: MICHAEL LICHATOWICH
Cage: 02388
Contractor
Telephone: 616-683-3377/219-236-5856
Cage: 02388
Ingredients
POLYISOCYANATE BASED ON HDI TRADESECRET #06-027 (VP = 7.5
Fraction By Weight: 75.0%
ACETATE ESTER (VP = 1.4 @ 20C
CAS: 88230-35-7
Fraction By Weight: 25.0%
1,6-DIISOCYANATOHEXANE (HEXAMETHYLENE DIISOCYANATE)
CAS: 822-06-0
RTECS: MO1740000
Fraction By Weight: 0.2%
ACGIH TLV: 0.005 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
VOC = 2.22 LB/GL
RTECS: 9999999VO
OSHA PEL NOT RELEVANT
ACGIH TLV: NOT RELEVANT
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: IRRIT, (RUNNY NOSE, SORE
THROAT, COUGH, CHEST DISCOMFORT, SHORTNESS OF BREATH, REDUCED LUNG
FUNCTION). BRONCHITIS, BRONCHIO SPASM, PULMONARY EDEMA, CHEMICAL
HYPERSENSITIVITY PNEUMONITIS, (FEVER CHILLS). ISOCYANATE
SENSITIZATION, (CHEST TIGHTNESS, WHEEZING, COUGH, SHORTNESS OF
BREATH, ASTHMA ATTACK). SKIN: *
Effects of Overexposure:* IRRIT, (RED SWELL, RASH, SCALE, BLISTER,
SENSITIZATION(. EYE: IRRIT, (TEAR, RED, SWELL). INGEST: IRRIT,
CORROSION. CHRONIC: INHAL: LUNG DAMAGE, DECREASED LUNG FUNCTION.
EYE: CORNEAL OPACITY.
Medical Cond Aggravated by Exposure:ASTHMA, BRONCHITIS, EMPHYSEMA,
HYPERREACTIVITY, SKIN ALLERGIES & XEMA.
First Aid
First Aid:EYE: FLUSH W/LUKEWARM WATER LOW PRESSURE >15 MIN. LIFT LIDS,
CALL DR/OPHTHALMOLOGIST IMMED. SKIN: REMOVE CONTAM CLOTHES, WASH
BEFORE REUSE. WASH THOROUGHLY W/SOAP (GREN TINCTURE SOAP
RECOMMENDED) & WA TER UNDER SAFETY SHOWER, GET MED AID. INHAL: GET
FRESH AIR, GIVE OXY/ARTIF RESP AS NEEDED, CALL DR. INGEST: DONT
INDUCE VOMIT, CALL DR IMMED.
Fire Fighting
Flash Point Method:TCC
Flash Point:135F,57C
Autoignition Temp:Autoignition Temp Text:NE
Lower Limits:1.0
Upper Limits:8.0
Extinguishing Media:DRY CHEMICAL, CO2, FOAM, WATER SPRAY.
Fire Fighting Procedures:WEAR FULL EMERGENCY EQUIPMENT W/SCBA &
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:HDI/OTHER HAZARDOUS VAPORS MAY BE
GENERATED. CLOSED CONTAINER MAY EXPLODE W/EXTREME HEAT OR BURST
W/WATER.
Accidental Release
Spill Release Procedures:EVAC/VENT AREA, ELIMINATE IGNITS. DIKE. NOTIFY
AUTHORITIES IF NECESSARY OR IF NEEDED. ABSORB. DECONTAM. ALLOW TO
REACT >10 MIN. COLLECT IN OPEN CNTNR. ADD MORE DECONTAM SOLUTION,
REMOVE TO SAFE PLACE. COVER LOOSELY. ALLOW TO STAND 24-48 HRS. **
Neutralizing Agent:TERIGITOL 20% WATER 80% AMMONIA 3-8% DETERGENT 2%
WATER 90-95%.
Handling
Handling and Storage Precautions:KEEP AWAY FROM IGNITS. GROUND CNTNRS
DURING STORAGE/TRANSFER. STORE IN TIGHTLY CLSD CNTNRS TO PREVENT
MOISTURE CONTAM. DONT RESEAL IF CONTAM ***
Other Precautions:MAY BE REQUIRED. *** SUSPECTED. STORE BETWEEN 50 &
81F.
Exposure Controls
Respiratory Protection:AIR PURIFYING OR FRESH AIR SUPPLIED.
Ventilation:YES
Protective Gloves:PERMIATION RESISTANT.
Eye Protection:SPLASH GOGGLES/FACE SHIELD.
Other Protective Equipment:APPROPRIATE CLOTHING & SKIN CREAMS.
Work Hygienic Practices:DONT WEAR CONTACTS.
Supplemental Safety and Health
MORE INFORMATION ON FILE. **WASH SPILL AREA W/DECOMTAM SOLUTION.
Chemical Properties
Boiling Pt:B.P. Text:327 TO 349F
Vapor Density:>AIR.
Spec Gravity:1.066
pH:NA
Viscosity:50SEC #4 FC
Evaporation Rate & Reference:
Percent Volatiles by Volume:30.57
Corrosion Rate:MINIMAL.
Stability
Stability Indicator/Materials to Avoid:YES
WATER, AMINES, STRONG BASES, ALCOHOLS, METAL COMPOUNDS & SURFACE ACTIVE
MATERIALS.
Stability Condition to Avoid:HIGH HEAT OR MOISTURE.
Hazardous Decomposition Products:CO2, CO, OXIDES OF NITROGEN, TRACES OF
HCN & HDI.
Conditions to Avoid Polymerization:CONTACT W/MOISTURE, OTHER ISOCYANATE
REACTING MATERIALS, & TEMPS >400F.
Disposal
Waste Disposal Methods:IN ACCORDANCE W/FEDERAL/STATE/LOCAL REGULATIONS.
INCINERATION PREFERRED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.